Removing transport safety packaging
Caution! Before use all parts of the transport
packaging must be removed.
1. Open loading door 2. Pull off adhesive strips
from inside machine on
top of drum.
3. Remove foil hose and polystyrene padding from the
machine.
Electrical connection
Details on mains voltage, type of current and the fuses
required should be taken from the rating plate. The rating
plate is fitted near the loading aperture (see “Product de-
scription” chapter).
Connect the machine to an earthed socket, in accordance
with current wiring regulations.
Warning! The manufacturer declines any
responsibility for damage or injury through failure
to comply with the above safety precautions.
Should the appliance power supply cable need to be
replaced, this must be carried out by an authorised service
engineer or a qualified electrician. .
The appliance is supplied with a 13 amp plug fitted. In the
event of having to change the fuse in the plug supplied,
a 13 amp ASTA approved BS 1363/A fuse must be used.
1
2
3
4
The wires in the mains lead are coloured in accordance
with the following code:
1 Blue - Neutral
2 cord clamp
3 Brown - Live
4 Green and Yellow - Earth
The wire coloured green and yellow must be connected
to the terminal marked with the letter «E» or by the earth
symbol
or coloured green and yellow.
The wire coloured blue must be connected to the terminal
«N» or coloured black.
The wire coloured brown must be connected to the ter-
minal marked «L» or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
Warning! A cut off plug inserted into a 13 amp
socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of safely.
Warning! The plug must be accessible after
installing the machine.
Permanent connection
In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3 mm between the switch contacts and of a type suitable
for the required load in compliance with the current elec-
trical regulations.
The switch must not break the yellow and green earth
cable at any point.