markings identifying the terminals in your plug,
proceed as follows:
1. Connect the wire coloured green and yellow to
the terminal marked either with the letter “E“ or
by the earth symbol
or coloured green and
yellow.
2. Connect the wire coloured blue to the terminal
either marked with the letter “N“ or coloured
black.
3. Connect the wire coloured brown to the
terminal either marked with the “L“ or coloured
red.
4. Check that no cut, or stray strands of wire is
present and the cord clamp (E) is secure over
the outer sheath.
Make sure the electricity supply voltage is the
same as that indicated on the appliance rating
plate.
5. Switch on the appliance.
The appliance is supplied with a 13 amp fuse (B).
In the event of having to change the fuse in the plug
supplied, a 13 amp ASTA approved (BS 1362)
fuse must be used.
WARNING! A cut off plug inserted
into a 13 amp socket is a serious
safety (shock) hazard. Ensure that it is
disposed of safely.
INSTALLATION OF THE APPLIANCE AND
DOOR REVERSAL
Please refer to separate instructions
on installation (ventilation
requirements, levelling) and door
reversal.
TECHNICAL DATA
Height 1845 mm
Width 595 mm
Depth 647 mm
Rising time 18 h
Voltage 230 - 240 V
Frequency 50 Hz
The technical information is situated in the rating
plate, on the external or internal side of the
appliance and in the energy label.
ENVIRONMENTAL CONCERNS
Recycle materials with the symbol . Put the
packaging in relevant containers to recycle it. Help
protect the environment and human health by
recycling waste of electrical and electronic
appliances. Do not dispose of appliances marked
with the symbol with the household waste.
Return the product to your local recycling facility or
contact your municipal office.