Zanussi ZRB34312XA User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
It is important to peri-
odically clean the de-
frost water drain hole
in the middle of the
refrigerator compart-
ment channel to pre-
vent the water over-
flowing and dripping
onto the food inside.
Defrosting of the freezer
The freezer compartment of this model, on the
other hand, is a "no frost" type. This means that
there is no buildup of frost when it is in opera-
tion, neither on the internal walls nor on the
foods.
The absence of frost is due to the continuous
circulation of cold air inside the compartment,
driven by an automatically controlled fan.
Troubleshooting
Caution! Before troubleshooting,
disconnect the power supply.
Only a qualified electrician or competent person
must do the troubleshooting that is not in this
manual.
Important! There are some sounds during
normal use (compressor, refrigerant circulation).
Problem Possible cause Solution
The appliance is noisy. The appliance is not installed prop-
erly.
Check if the appliance stands stable
(all the feet should be on the floor).
The appliance does not op-
erate.
The plug is not connected to the
mains socket correctly.
Connect the plug to the mains socket
correctly.
The appliance has no power. There
is no voltage in the mains socket.
Connect a different electrical appli-
ance to the mains socket.
Contact a qualified electrician.
The light device does not
work.
The light device is in stand-by. Close and open the door.
The unit is defective. Refer to "Replacing the control unit".
The compressor operates
continually.
The temperature is not set correctly. Set a higher temperature.
The door is not closed correctly. Refer to "Closing the door".
The door has been opened too fre-
quently.
Do not keep the door open longer
than necessary.
The food temperature is too high. Let the food temperature decrease to
room temperature before storage.
The room temperature is too high. Decrease the room temperature.
Water flows on the rear
plate of the refrigerator.
During the automatic defrosting
process, frost defrosts on the rear
plate.
This is correct.
Water flows into the refrig-
erator.
The water outlet is clogged. Clean the water outlet.
Products prevent that water flows
into the water collector.
Make sure that products do not touch
the rear plate.