17
CHANGE OF GAS
Your cooker is foreseen to work with natural
gas, propane or butane. It is not foreseen
for butane or propane air.
For changing the gas type it is necessary to:
• replace the nozzles (hob);
• adjust the minimum level;
• check the gas connection
SPECIFICATION NOZZLES NO. 1
Cons.
BURNERS
NOM.
POWER
(kW)
Reduced
power
(Kw)
TYPE OF GAS
PRESSURE
(mbar)
NOZZLE
DIAM.
(mm)
Kg/h m
3
/h
APID
2,60 0.72
ATURAL GAS G 13
ATURAL GAS G 20
LPG G 30
13
20
30
1,20
1,12
0,86
EMI-
RAPID
2,00
0.43
ATURAL GAS G 13
ATURAL GAS G 20
LPG G 30
13
20
30
1,05
0,96
0,71
UXILIARY
1,00 0.35
ATURAL GAS G 13
ATURAL GAS G 20
LPG G 30
13
20
30
0,80
0,70
0,50
VEN
2,55 1.00
ATURAL GAS G 13
ATURAL GAS G 20
LPG G 30
13
20
30
1,50
1,35
0,92
RILL
2,00 -
ATURAL GAS G 13
ATURAL GAS G 20
LPG G 30
13
20
30
1,25
1,15
0,80
Stick the label delivered with the appliance
(spare nozzles, corresponding to the type of gas
used).
Comments to this Manuals