Warning! Make sure the flame does not
go out when you quickly turn the knob
from the maximum position to the minimum
position.
Electrical connection
Make sure that the rated voltage and type of
power on the rating plate agree with the
voltage and the power of the local power
supply.
This appliance is supplied with a mains ca-
ble. It has to be supplied with a correct plug
which can hold the load that the rating plate
rates. Make sure that you install the plug in a
correct socket.
Always use a correctly installed shockproof
socket.
Make sure that there is an access to the
mains plug after the installation.
Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
There is a risk of fire when the appliance is
in connection with an extension cable, an
adapter or a multiple connection. Make sure
that the ground connection agrees with the
standards and regulations.
Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue neutral
cable to the terminal with a letter "N" on it.
Connect the brown (or black) phase cable to
the terminal which has a letter "L". Keep the
phase cable connected at all times.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make sure
that the cable section is applicable to the volt-
age and the working temperature. The yellow/
green earth wire must be approximately 2 cm
longer than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
30 mm
470 mm
A
B
A) supplied seal
B) supplied bracket
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in case
a technical assistance intervention is necessa-
ry.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections