Dimensions are given in mm.
Building In
Building over a cupboard or
drawer
If the hob is to be installed above a cupboard or drawer
it will be necessary to fit a heat resistant board below
the base of the hob on the underside of the work surface.
It is also recommended to carry out the electrical
connection to the hob as shown in diagrams 1 and 2.
Rectangular cut-out size for hob
A) End of shaft with nut
B) Washer
C) Elbow
FO
0814
Gas Connection
Connection to the gas supply should be with either rigid
or semi-rigid pipe, i.e. steel or copper.
The connection should be suitable for connecting to RC
1/2 (1/2 BSP male thread).
When the final connection has been made, it is essential
that a thorough leak test is carried out on the hob and
installation.
Ensure that the main connection pipe does not exert
any strain on the hob.
It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to
the hob connecting pipe.
Failure to ensure the correct assembly will cau-
se leakage of gas.