Commissioning
When the hob has been fully installed it will be
necessary to check the minimum flame setting. To do
this, follow the procedure below.
- Turn the gas tap to the MAX position and ignite.
- Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times. If
the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Remove the control knob, insert a thin
bladed screwdriver down the centre of the
gas tap control shaft and turn the
adjustment screw until the flame is steady
and does not extinguish, when the knob is
turned from MIN to MAX. Repeat this
procedure for all burners.
Pressure Testing
Remove left hand pan support and front left
burner cap and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite
another burner.
The pressure reading should be nominally
20mbar and must be between 17 mbar and
25mbar.
Turn off the burner supplies.
It is important to note that this model is designed for
use with natural gas but can be converted for use
with butane or propane gas providing the correct
injectors are fitted. The gas rate is adjusted to suit.
Method
Ensure that the gas taps are in the 'OFF' position
Isolate the hob from the electrical supply
Remove all pan supports, burner caps, rings, crowns
and control knobs.
With the aid of a 7mm box spanner the burner
injectors can then be unscrewed and replaced by
the appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely
tighten down the by pass adjustment screw, which is
located down the centre of the gas tap control shaft.
Upon completion stick the replacement rating plate
on the under side of the hob.
IMPORTANT
The replacement/conversion of the gas hob should
only be undertaken by a competent person.