the water hardness is soft it is not necessary to
use a water softener.
To know the water hardness in your area, con-
tact your local water authority.
Use the correct quantity of the water softener.
Obey the instructions that you find on the pack-
aging of the product.
Technical data
Dimensions Width / Height / Depth 600 / 850 / 600 mm
Electrical connection Voltage
Overall power
Fuse
Frequency
230 V
2300 W
10 A
50 Hz
Water supply pressure Minimum
Maximum
0,5 bar (0,05 MPa)
8 bar (0,8 MPa)
Level of protection against ingress of solid particles and moisture IPX4
Water supply
1)
Cold water
Maximum Load Cotton 5 kg
Spin Speed Maximum 800 rpm (ZWY180)
1000 rpm (ZWY1100)
1) Connect the water inlet hose to a water tap with a 3/4'' thread.
Consumption values
The data of this table are approximate. Different causes can change the data: the quantity and
type of laundry, the water and ambient temperature.
Programmes Load
(kg)
Energy con-
sumption
(kWh)
Water con-
sumption (li-
tre)
Approxi-
mate pro-
gramme
duration
(minutes)
Remaining
moisture
(%)
1)
ZWY180
Remaining
moisture
(%)
1)
ZWY1100
Cottons 60 °C 5 1.20 58 120 66 60
Cottons 40 °C 5 0.780 58 120 66 60
Synthetics 40
°C
2,5 0.65 48 80 37 37
Delicates 40 °C 2,5 0.55 53 70 37 37
Wool/Hand
wash 30 °C
1 0.40 48 54 37 32
Standard cotton programmes
Standard 60 °C
cotton
5 0.96 49 214 66 60
Standard 60 °C
cotton
2,5 0.81 33 165 66 60
Standard 40 °C
cotton
2,5 0.59 33 130 66 60
1) At the end of spin phase.