Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 42
Semi-rapid 32
Auxiliary 28
Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 7,7 kW
Gas replacement: G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar = 536 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2H3+
Gas connection: G 1/2"
Appliance class: 3
Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
1/100 mm
Rapid 2,9 0,75 119
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71
Energy efficiency
Product information according to EU 66/2014
Model identification ZGO63414BA